ACCUDYNA / MULTI-AXIS MOTION SYSTEMS

FDA-334Three-Axis Precision Motion Simulator with Continuous Roll, Pitch & Yaw

FDA-334 is a three-axis continuous-motion simulator built around inner, middle, and outer axes for Roll, Pitch, and Yaw movement. The published parameter sheet highlights precision positioning, locking capability, controlled rate motion, and multi-axis dynamic performance for demanding UUT test setups.

3 AxesRoll · Pitch · Yaw
20 kgMax UUT Weight
±150°/sRate Range on All Axes
34 + 82Electrical Lines to UUT
INNER ROLL / MIDDLE PITCH / OUTER YAW ACCUDYNA FDA-334 three-axis precision motion simulator
RATE ACCURACY & STABILITY< 15 ppmOver 360° on all axes
AXIS ACCELERATION>200 / >150 / >200°/s² · Inner / Middle / Outer
01Three Continuous Axes

Inner, middle, and outer axes provide continuous angular freedom for Roll, Pitch, and Yaw motion.

02Position + Locking Modes

The parameter sheet separately lists precision values for both positioning and locking performance.

03Precision Rate Control

Each axis is listed with ±150°/s range, fine rate resolution, and accuracy/stability better than 15 ppm.

04Heavy-Duty UUT Interface

20 kg UUT capacity with multiple electrical lines routed to the test article.

PRODUCT OVERVIEW

Three-axis precision.Compact, continuous multi-axis motion.

The FDA-334 parameter sheet presents a precision three-axis simulator with inner Roll, middle Pitch, and outer Yaw axes. All three axes provide continuous angular freedom.

The UUT specification block lists a 20 kg maximum UUT weight, 263 × 240 × 240 mm UUT dimensions, a stainless steel 420 table top, and electrical routing to the UUT through 34 lines at 3 A and 82 lines at 2 A.

The published axis performance includes separate values for position, locking, rate, dynamic acceleration, and orientation error, making the platform suitable for controlled multi-axis laboratory test scenarios.

The parameter sheet also lists a table-top distance from floor of 1100 mm and an axes-intersection distance from floor of 1200 mm.
ENGINEERING ARCHITECTURE

Three-axis test platform.Built around measured axis performance.

System attributes and performance categories stated in the manufacturer parameter sheet.

01 / AXES
↻

Inner · Middle · Outer Axes

The simulator is organized around three motion axes corresponding to Roll, Pitch, and Yaw.

  • Inner axis: Roll
  • Middle axis: Pitch
  • Outer axis: Yaw
  • Continuous angular freedom
02 / POSITION
◉

Precision Positioning & Locking

Separate specifications are published for position accuracy/repeatability and for locking accuracy/repeatability.

  • Position accuracy: ±5 arcsec
  • Position repeatability: ±2 arcsec
  • Locking accuracy: ±5 arcsec
  • Locking repeatability: ±2 arcsec
03 / RATE
◎

Controlled Rate Motion

All three axes share the same published rate range and resolution, with stability/accuracy stated over 360 degrees.

  • Range: ±150 °/s
  • Resolution: ±0.0001 °/s
  • Accuracy & stability: < 15 ppm
  • Same on all three axes
04 / UUT
◇

UUT Mounting Interface

The parameter sheet lists the physical and electrical characteristics of the UUT interface.

  • Max UUT weight: 20 kg
  • UUT size: 263 × 240 × 240 mm
  • Table-top material: Stainless Steel 420
  • 34 lines 3A + 82 lines 2A
±150°/s

All three axes

±0.0001°/s

All three axes

±2arcsec

All three axes

<5arcsec

Published orientation error

FDA-334 MOTION PERFORMANCE SUMMARY3-AXIS SYSTEM
ROLL±150°/s
PITCH±150°/s
YAW±150°/s
34 × 3A82 × 2A20 kg UUTEnglish SW
SYSTEM HIGHLIGHTS

Balanced precision.Identical core rate specs on all axes.

The published parameter sheet shows matching core rate behavior across all three axes, with shared range, resolution, and accuracy/stability values. Dynamic acceleration differs by axis, with the inner and outer axes listed above 200°/s² and the middle axis above 150°/s².

  • Continuous motion on all three axes
  • Position and locking specification blocks
  • Rate accuracy & stability over 360°
  • English software language listed
Operating temperature is listed as 20 to 24 °C, and storage temperature is listed as 0 to 50 °C.
APPLICATION-ORIENTED CAPABILITIES

What the FDA-334 sheet tells you.Key capabilities at a glance.

Derived directly from the parameter categories and UUT specification block.

01

Continuous Roll

The inner axis is listed as continuous and supports full-time rotational motion.

02

Continuous Pitch

The middle axis is also continuous with the same core position and rate precision class.

03

Continuous Yaw

The outer axis completes the three-axis set with continuous angular freedom.

04

Precision Positioning

Position accuracy is listed as ±5 arcsec and repeatability as ±2 arcsec on each axis.

05

Locking Performance

The sheet separately specifies locking accuracy and repeatability for stabilized conditions.

06

Controlled Rate Tests

All axes are listed with ±150°/s range and ±0.0001°/s resolution.

07

Dynamic Motion

The system publishes axis-specific no-load acceleration performance values.

08

Instrumented UUT Support

Electrical lines to the UUT support connected and instrumented test articles.

09

Lab Installation

The sheet includes floor-referenced geometry, dimensions, weight, and power supply information.

TECHNICAL SPECIFICATIONS

FDA-334parameter sheet.

Values below follow the published manufacturer sheet. Axis-dependent values are shown separately where applicable.

01UUT SPECIFICATIONS
Table Top Distance from Floor1100 mm
Axes Intersection Distance from Floor1200 mm
Electrical Lines to UUT34 lines 3A, 82 lines 2A
Max UUT Weight20 kg
UUT Dimensions(L × W × H) 263 × 240 × 240 mm³
Table Top MaterialStainless Steel 420
02DEGREES OF FREEDOM
Inner AxisRoll · Continuous
Middle AxisPitch · Continuous
Outer AxisYaw · Continuous
03POSITION
Accuracy · Inner / Middle / Outer±5 / ±5 / ±5 arcsec
Repeatability · Inner / Middle / Outer±2 / ±2 / ±2 arcsec
Command Resolution · Inner / Middle / Outer1 / 1 / 1 arcsec
04LOCKING
Accuracy · Inner / Middle / Outer±5 / ±5 / ±5 arcsec
Repeatability · Inner / Middle / Outer±2 / ±2 / ±2 arcsec
05RATE
Range · Inner / Middle / Outer±150 / ±150 / ±150 °/s
Resolution · Inner / Middle / Outer±0.0001 / ±0.0001 / ±0.0001 °/s
Accuracy & Stability (over 360°)<15 / <15 / <15 ppm
06DYNAMIC
Acceleration (No Load) · Inner / Middle / Outer>200 / >150 / >200 °/s²
07ORIENTATION ERROR
Orthogonality<5 arcsec
08OPERATING & PHYSICAL CONDITIONS
Operating Temperature20 to 24 °C
Storage Temperature0 to 50 °C
Rate Table Dimensions(L × W × H) 1600 × 1060 × 1060 mm³
Rate Table Weight390 kg
Rate Table Weight with Box450 kg
Power Supply220 VAC, 50 Hz
09SOFTWARE
Language of SoftwareEnglish
The parameter sheet states that the specifications identified in this data sheet are representative of standard systems.
OFFICIAL ACCUDYNA DOCUMENT 1-PAGE PDF

FDA-334Official Parameter Sheet.

One concise manufacturer sheet containing the complete UUT data, Roll / Pitch / Yaw specifications, positioning and locking values, rate performance, physical installation data, and power requirements.

PRODUCT FDA-334
DOCUMENT 1 Original Page
CONTENT Full Parameter Table
No stacked-page preview is used here because this product has a single-page official datasheet.
PLATFORM SUMMARY

Core published attributes.Everything important at a glance.

The official sheet emphasizes continuous three-axis motion, precision position and locking behavior, identical core rate specifications across axes, and UUT support through a robust electrical interface.

01

Continuous Roll / Pitch / Yaw motion

02

Separate Position and Locking specs

03

Rate accuracy & stability better than 15 ppm

04

34 lines 3A + 82 lines 2A to the UUT

05

Stainless Steel 420 table top

FAQ

FDA-334at a glance.

Answers based on the official parameter sheet.

How many axes does the FDA-334 provide?
Three continuous axes: inner Roll, middle Pitch, and outer Yaw.
What is the maximum UUT weight?
20 kg.
What are the published rate ranges?
±150°/s on the inner, middle, and outer axes.
What position performance is listed?
The sheet lists ±5 arcsec accuracy, ±2 arcsec repeatability, and 1 arcsec command resolution on all three axes.
What is the no-load acceleration?
Greater than 200°/s² on the inner and outer axes, and greater than 150°/s² on the middle axis.
What electrical interface is listed for the UUT?
34 lines at 3 A and 82 lines at 2 A.
What are the physical dimensions and weight?
Rate table dimensions are listed as 1600 × 1060 × 1060 mm³, with a 390 kg rate-table weight and 450 kg boxed weight.
What software language is listed?
English.
ENGINEER YOUR TEST PLATFORM

Need FDA-334for your application?

Discuss UUT size, electrical-line requirements, installation geometry, axis performance, and application-specific motion requirements for your next multi-axis precision test setup.

Request a Quote →
334