ACCUDYNA / MULTI-AXIS MOTION SYSTEMS

FDA-335-V1Three-Axis Rate Table with Controlled Roll, Pitch & Yaw Motion

FDA-335-V1 is a three-axis rate-table platform with dedicated inner, middle, and outer axes for Roll, Pitch, and Yaw. The official parameter sheet highlights axis-specific angular freedom, position performance, rate control, dynamic bandwidth, UUT wiring capacity, and installation-ready physical specifications.

3 AxesRoll · Pitch · Yaw
7.5 kgMax UUT Weight
±120°/sRate Range on All Axes
92 + 6Electrical Lines to UUT
INNER ROLL / MIDDLE PITCH / OUTER YAW ACCUDYNA FDA-335-V1 three-axis rate table
ANGULAR FREEDOM±60° / ±40° / ±95°Roll · Pitch · Yaw
RATE ACCURACY< 0.5 °/sAll axes
01Three Dedicated Axes

Inner Roll, middle Pitch, and outer Yaw axes are individually specified in the manufacturer sheet.

02Controlled Angular Travel

Each axis has its own angular-freedom envelope instead of unlimited continuous rotation.

03Precision Rate Performance

All axes share the same published rate range, resolution, and rate-accuracy values.

04Instrumented UUT Support

The table-top interface supports both 3 A and 7 A electrical lines to the UUT.

PRODUCT OVERVIEW

Three-axis control.Compact rate-table architecture.

The FDA-335-V1 product sheet presents a compact three-axis rate table with inner Roll, middle Pitch, and outer Yaw axes. Unlike a continuous-rotation simulator, the axes here use bounded angular travel values of ±60°, ±40°, and ±95° respectively.

The table-top specification block lists a 7.5 kg maximum UUT weight, 236 × 275 × 282 mm UUT dimensions, and an aluminum hard-anodized table top. UUT connectivity includes 92 lines at 3 A and 6 lines at 7 A.

The published performance blocks separately cover position, rate, dynamic bandwidth and acceleration, orientation error, and the main operating and physical conditions.

The official sheet also lists a table-top distance from floor of 900 mm and an axes-intersection distance from floor of 960 mm.
ENGINEERING ARCHITECTURE

Structured around three motion axes.Each axis independently specified.

System attributes and performance categories stated in the official ACCUDYNA product sheet.

01 / AXES
↻

Roll · Pitch · Yaw Platform

The platform uses three motion axes with distinct angular-freedom envelopes.

  • Inner axis: Roll
  • Middle axis: Pitch
  • Outer axis: Yaw
  • Axis-specific angular travel limits
02 / POSITION
◉

Position Performance

All three axes share the same published position-performance values.

  • Accuracy: ±60 arcsec
  • Repeatability: ±60 arcsec
  • Command resolution: 36 arcsec
  • Same values on all axes
03 / RATE
◎

Rate Control

Each axis is rated with the same range, resolution, and accuracy values for controlled rate motion.

  • Range: ±120 °/s
  • Resolution: ±0.01 °/s
  • Accuracy: < 0.5 °/s
  • Same on all three axes
04 / UUT
◇

UUT Interface

The table-top and electrical interface data define how the test article is mounted and wired.

  • Max UUT weight: 7.5 kg
  • UUT size: 236 × 275 × 282 mm
  • Table-top material: hard-anodized aluminum
  • 92 lines 3 A + 6 lines 7 A
±120°/s

All three axes

±0.01°/s

All three axes

20 / 30 / 15Hz

Roll · Pitch · Yaw

<30arcsec

Published orientation error

FDA-335-V1 MOTION PERFORMANCE SUMMARY3-AXIS RATE TABLE
ROLL±120°/s
PITCH±120°/s
YAW±120°/s
92 × 3A6 × 7A7.5 kg UUT220 VAC
SYSTEM HIGHLIGHTS

Symmetric core rate specs.Axis-specific angular travel.

The official sheet shows the same published rate range, resolution, and accuracy across all three axes, while angular freedom differs per axis. Dynamic bandwidth is listed as 20 Hz for Roll, 30 Hz for Pitch, and 15 Hz for Yaw, with acceleration above 300 °/s² for all axes.

  • Three individually bounded motion axes
  • Same published rate specs on all axes
  • Acceleration above 300 °/s² on all axes
  • Hard-anodized aluminum table top
Operating temperature is listed as -10 ~ +50 °C, and storage temperature is listed as -20 ~ +60 °C.
APPLICATION-ORIENTED CAPABILITIES

What the FDA-335-V1 sheet shows.Key capabilities at a glance.

Derived directly from the published rate-table parameter blocks.

01

Three-Axis Motion

Roll, Pitch, and Yaw movement are all separately defined in the manufacturer sheet.

02

Controlled Angular Travel

The platform provides bounded angular freedom rather than continuous rotation.

03

Positioning Tasks

Each axis has a published accuracy, repeatability, and command-resolution value.

04

Rate Testing

All axes are listed with ±120°/s range and ±0.01°/s resolution.

05

Dynamic Motion

Dynamic blocks define bandwidth and no-load acceleration by axis.

06

Instrumented UUT Support

Electrical lines to the UUT support wired test articles and interfaces.

07

Compact Lab Integration

The official sheet includes floor-referenced geometry, dimensions, weight, and power data.

08

Axis Geometry Management

The axes-intersection distance from floor is explicitly specified.

09

Broad Environment Range

Operating and storage temperature ranges are listed directly in the product sheet.

TECHNICAL SPECIFICATIONS

FDA-335-V1parameter sheet.

Values below follow the official ACCUDYNA product sheet. Axis-dependent values are shown separately where applicable.

01TABLE-TOP SPECIFICATIONS
Table Top Distance from Floor900 mm
Axes Intersection Distance from Floor960 mm
Electrical Lines to UUT92 lines 3 A, 6 lines 7 A
Max UUT Weight7.5 kg
UUT Dimensions(L × W × H) 236 × 275 × 282 mm³
Table Top MaterialAluminum (Hard Anodized)
02DEGREES OF FREEDOM
Inner AxisRoll · ±60°
Middle AxisPitch · ±40°
Outer AxisYaw · ±95°
03POSITION
Accuracy · Inner / Middle / Outer±60 / ±60 / ±60 arcsec
Repeatability · Inner / Middle / Outer±60 / ±60 / ±60 arcsec
Command Resolution · Inner / Middle / Outer36 / 36 / 36 arcsec
04RATE
Range · Inner / Middle / Outer±120 / ±120 / ±120 °/s
Resolution · Inner / Middle / Outer±0.01 / ±0.01 / ±0.01 °/s
Accuracy · Inner / Middle / Outer<0.5 / <0.5 / <0.5 °/s
05DYNAMIC
Bandwidth (-3 dB, No Load) · Inner / Middle / Outer20 / 30 / 15 Hz
Acceleration (No Load) · Inner / Middle / Outer>300 / >300 / >300 °/s²
06ORIENTATION ERROR
Orthogonality · Middle / Outer<30 / <30 arcsec
07OPERATING & PHYSICAL CONDITIONS
Operating Temperature-10 ~ +50 °C
Storage Temperature-20 ~ +60 °C
Dimensions(L × W × H) 800 × 800 × 1300 mm³
Weight233 kg
Power Supply220 VAC, 50 Hz
The official product sheet presents these values as the representative specifications for the FDA-335-V1 system.
OFFICIAL ACCUDYNA DOCUMENT 1-PAGE PDF

FDA-335-V1Official Product Sheet.

One concise manufacturer sheet containing the complete table-top specification block, Roll / Pitch / Yaw axis data, position and rate performance, dynamic bandwidth, environmental conditions, and physical dimensions.

PRODUCT FDA-335-V1
DOCUMENT 1 Original Page
CONTENT Full Parameter Table
This single-page product sheet uses the improved one-page catalog layout you approved for one-page PDFs.
PLATFORM SUMMARY

Core published attributes.Fast access to the essentials.

The official sheet emphasizes bounded angular freedom on all three axes, symmetric core rate specifications, strong UUT wiring capacity, and a compact physical footprint for laboratory integration.

01

Three axes with ±60° / ±40° / ±95° travel

02

Rate range ±120 °/s on all axes

03

Bandwidth 20 / 30 / 15 Hz

04

92 lines 3 A + 6 lines 7 A to the UUT

05

Hard-anodized aluminum table top

FAQ

FDA-335-V1at a glance.

Answers based on the official product sheet.

How many axes does the FDA-335-V1 provide?
Three axes: inner Roll, middle Pitch, and outer Yaw.
Is angular freedom continuous?
No. The product sheet lists bounded angular freedom of ±60° on Roll, ±40° on Pitch, and ±95° on Yaw.
What is the maximum UUT weight?
7.5 kg.
What are the published rate ranges?
±120°/s on the inner, middle, and outer axes.
What are the table-top electrical lines to the UUT?
92 lines at 3 A and 6 lines at 7 A.
What dynamic performance is listed?
Bandwidth is 20 Hz for Roll, 30 Hz for Pitch, and 15 Hz for Yaw, while acceleration is above 300°/s² on all three axes.
What are the physical dimensions and weight?
Dimensions are listed as 800 × 800 × 1300 mm³ and weight as 233 kg.
What environmental conditions are listed?
Operating temperature is -10 ~ +50 °C and storage temperature is -20 ~ +60 °C.
ENGINEER YOUR TEST PLATFORM

Need FDA-335-V1for your application?

Discuss axis travel limits, UUT dimensions, electrical-line requirements, bandwidth needs, and installation constraints for your next three-axis rate-table setup.

Request a Quote →
335